Конвертор IndraDrive C HCS02

Technical data
HCS02.1E-W0012 HCS02.1E-W0028 HCS02.1E-W0054 HCS02.1E-W0070
Power
Continous current
[A]
4,5 12 20,6 28
Maximum current
[A]
11,5 28,3 54 70,8
Motor nominal power typ.
[kW]
1,5 4 7,5 11
Mains voltage
1 AC
200...250 V
3 AC
200...500 V
Tolerances
[%]
± 10 %
Frequency
50...60 Hz
Frequency tolerances
Hz]
± 2 Hz
Continous input mains current
[A]
6 13 20 30
Dependence of output on mains voltage
ULN < 400 V
1 % power reduction per 4 V
ULN > 400 V
1 % power gain per 5 V
Mains contactor
external
DC bus
Continuous output with choke
[kW]
2,1 5,1 10 14
Max. output with choke
[kW]
5 10 16 19
Continuous output without choke
[kW]
2,1 5,1 7 9
Max. output without choke
[kW]
5 8 12 14
Switching frequency/max. output frequency
4 kHz
0...400 Hz
8 kHz
0...800 Hz
12 kHz
0...1200 Hz
16 kHz
0...1600 Hz
Output voltage
[V]
3 x AC 0...main voltage V
DC bus capacity
[mF]
0,135 0,27 0,54 0,675
DC bus voltage
[V] DC
Main voltage x 1,41
Converter/inverter combination
Brake chopper / resistor
Brake resistor
Internal internal/external
Brake chopper
Internal
Braking Energy Consumption
[kWs]
1 5 9 13
Continuous braking power
[kW]
0,05 0,15 0,35 0,5
Maximum braking power
[kW]
4 10 18 25
Control Voltage
Control Voltage
external
24V ± 20%
Internal
24V ± 10%
Power consumption without control unit and motor brake
[W]
12 14 23
Protection
Category Total
IP20 (IEC529)
Degree of contamination
2 (EN50178)
EMC
EN61800-3
Cooling system
forced ventilated
Standards
Certification
EN61800-5-1
UL 508 C
Canadian National Standard(s) C22.2 No. 14-05
Weight
Weight
[kg]
2,9 3,8 6,7 6,8
Ambient conditions
Ambient temp. operation
[°C]
0 ... 40 °C
Derating [°C]
0 ... 55 °C
Ambient temp. storage
[°C]
-25...55 °C
Relative humidity operation
[%]
 5...95 %
Relative humidity storage
[%]
 5...95 %
Installation height
[m]
1000
[m] Derating
4000

All data for nominal rating at 3 AC 400 V mains voltage and 4 kHz switching frequency