Конверторы
- Extremely high overload capacity
- Power range from 1.5 kW to 75 kW with maximum current from 12 A to 210 A
- Can be connected to inverters for cost-effective solutions
- Direct mains connection from 200 V to 500 V
The IndraDrive C series of converters integrate inverter and power supply in one unit. The compact construction contains additional mains connection components, making it particularly suitable for single-axis applications.
HCS02.1E-W0012 | HCS02.1E-W0028 | HCS02.1E-W0054 | HCS02.1E-W0070 | ||
Power | |||||
Continous current
|
[A]
|
4,5 | 12 | 20,6 | 28 |
Maximum current
|
[A]
|
11,5 | 28,3 | 54 | 70,8 |
Motor nominal power typ.
|
[kW]
|
1,5 | 4 | 7,5 | 11 |
Mains voltage
|
1 AC
|
200...250 V | |||
3 AC
|
200...500 V | ||||
Tolerances
|
[%]
|
± 10 % | |||
Frequency
|
50...60 Hz | ||||
Frequency tolerances
|
Hz]
|
± 2 Hz | |||
Continous input mains current
|
[A]
|
6 | 13 | 20 | 30 |
Dependence of output on mains voltage
|
ULN < 400 V
|
1 % power reduction per 4 V | |||
ULN > 400 V
|
1 % power gain per 5 V | ||||
Mains contactor
|
external | ||||
DC bus | |||||
Continuous output with choke
|
[kW]
|
2,1 | 5,1 | 10 | 14 |
Max. output with choke
|
[kW]
|
5 | 10 | 16 | 19 |
Continuous output without choke
|
[kW]
|
2,1 | 5,1 | 7 | 9 |
Max. output without choke
|
[kW]
|
5 | 8 | 12 | 14 |
Switching frequency/max. output frequency
|
4 kHz
|
0...400 Hz | |||
8 kHz
|
0...800 Hz | ||||
12 kHz
|
0...1200 Hz | ||||
16 kHz
|
0...1600 Hz | ||||
Output voltage
|
[V]
|
3 x AC 0...main voltage V | |||
DC bus capacity
|
[mF]
|
0,135 | 0,27 | 0,54 | 0,675 |
DC bus voltage
|
[V] DC
|
Main voltage x 1,41 | |||
Converter/inverter combination
|
• | ||||
Brake chopper / resistor | |||||
Brake resistor
|
Internal | internal/external | |||
Brake chopper
|
Internal | ||||
Braking Energy Consumption
|
[kWs]
|
1 | 5 | 9 | 13 |
Continuous braking power
|
[kW]
|
0,05 | 0,15 | 0,35 | 0,5 |
Maximum braking power
|
[kW]
|
4 | 10 | 18 | 25 |
Control Voltage | |||||
Control Voltage
|
external
|
24V ± 20% | |||
Internal
|
24V ± 10% | ||||
Power consumption without control unit and motor brake
|
[W]
|
12 | 14 | 23 | |
Protection | |||||
Category Total
|
IP20 (IEC529) | ||||
Degree of contamination
|
2 (EN50178) | ||||
EMC
|
EN61800-3 | ||||
Cooling system
|
forced ventilated | ||||
Standards | |||||
Certification
|
EN61800-5-1 | ||||
UL 508 C | |||||
Canadian National Standard(s) C22.2 No. 14-05 | |||||
Weight | |||||
Weight
|
[kg]
|
2,9 | 3,8 | 6,7 | 6,8 |
Ambient conditions | |||||
Ambient temp. operation
|
[°C]
|
0 ... 40 °C | |||
Derating [°C]
|
0 ... 55 °C | ||||
Ambient temp. storage
|
[°C]
|
-25...55 °C | |||
Relative humidity operation
|
[%]
|
5...95 % | |||
Relative humidity storage
|
[%]
|
5...95 % | |||
Installation height
|
[m]
|
1000 | |||
[m] Derating
|
4000 |
All data for nominal rating at 3 AC 400 V mains voltage and 4 kHz switching frequency
HCS03.1E-W0070 | HCS03.1E-W0100 | HCS03.1E-W0150 | HCS03.1E-W0210 | ||
Power | |||||
Continous current
|
[A]
|
45 | 73 | 95 | 145 |
Maximum current
|
[A]
|
70 | 100 | 150 | 210 |
Motor nominal power typ.
|
[kW]
|
22 | 37 | 45 | 75 |
Mains voltage
|
3 AC
|
||||
Tolerances
|
[%]
|
||||
Frequency
|
50...60 Hz | ||||
Frequency tolerances
|
Hz]
|
± 2 Hz | |||
Continous input mains current
|
[A]
|
50 | 80 | 106 | 146 |
Dependence of output on mains voltage
|
ULN < 400 V
|
1 % power reduction per 4 V | |||
ULN > 400 V
|
1 % power gain per 5 V | ||||
Mains contactor
|
external | ||||
DC bus | |||||
Continuous output with choke
|
[kW]
|
25 | 43 | 56 | 85 |
Max. output with choke
|
[kW]
|
40 | 59 | 89 | 124 |
Continuous output without choke
|
[kW]
|
13 | 24 | 34 | 47 |
Max. output without choke
|
[kW]
|
20 | 33 | 54 | 68 |
Switching frequency/max. output frequency
|
4 kHz
|
0...400 Hz | |||
8 kHz
|
0...800 Hz | ||||
12 kHz
|
0...1200 Hz | ||||
16 kHz
|
0...1600 Hz | ||||
Output voltage
|
[V]
|
||||
DC bus capacity
|
[mF]
|
0,94 | 1,44 | 1,88 | 4,7 |
DC bus voltage
|
[V] DC
|
Main voltage x 1,41 | |||
Converter/inverter combination
|
• | ||||
Brake chopper / resistor | |||||
Brake resistor
|
|||||
Brake chopper
|
Internal | ||||
Braking Energy Consumption
|
[kWs]
|
42 | 63 | 97 | 137 |
Continuous braking power
|
[kW]
|
13,2 | 18,9 | 25,2 | 42,6 |
Maximum braking power
|
[kW]
|
4 | 10 | 18 | 25 |
Control Voltage | |||||
Control Voltage
|
external
|
24V ± 20% | |||
Internal
|
24V | ||||
Power consumption without control unit and motor brake
|
[W]
|
22,5 | 25 | 30 | |
Protection | |||||
Category Total
|
IP20 (IEC529) | ||||
Degree of contamination
|
2 (EN50178) | ||||
EMC
|
EN61800-3 | ||||
Cooling system
|
forced ventilated | ||||
Standards | |||||
Certification
|
EN61800-5-1 | ||||
UL 508 C | |||||
Canadian National Standard(s) C22.2 No. 14-05 | |||||
Weight | |||||
Weight
|
[kg]
|
13 | 20 | 20 | 38 |
Ambient conditions | |||||
Ambient temp. operation
|
[°C]
|
0 ... 40 °C | |||
Derating [°C]
|
0 ... 55 °C | ||||
Ambient temp. storage
|
[°C]
|
-25...55 °C | |||
Relative humidity operation
|
[%]
|
5...95 % | |||
Relative humidity storage
|
[%]
|
5...95 % | |||
Installation height
|
[m]
|
1000 | |||
[m] Derating
|
4000 |
All data for nominal rating at 3 AC 400 V mains voltage and 4 kHz switching frequency
The new HCS04 power units complete Rexroth’s successful IndraDrive C converter series in the higher power range. Performances between 50 W and 630 kW are covered on a standard drive platform. In combination with the IndraDrive control units and their extensive firmware functionalities integrated solutions are realized throughout a wide power range.Technical data
HCS04.2E-F0290 | HCS04.2E-F0350 | HCS04.2E-F0420 | HCS04.2E-F0520 | HCS04.2E-F0640 |
HCS04.2E-F0790 | HCS04.2E-F1010 | HCS04.2E-F1040 | HCS04.2E-F1540 | HCS04.2E-W0290 |
HCS04.2E-W0350 | HCS04.2E-W0420 | HCS04.2E-W0520 | HCS04.2E-W0640 | HCS04.2E-W0790 |
HCS04.2E-W1010 | HCS04.2E-W1040 | HCS04.2E-W1540 |
All data for nominal rating at 3 AC 400 V mains voltage and 4 kHz switching frequency